The duplication, or more, of points in distributors was to avoid contact bounce. The coil really needs a single change of state “closed to open” to generate the spark and as rpm rises the number of contacts needed causes the contacts to bounce open as they close changing the current flow through the coil. Having 2 sets halves the number of close/open each ...